***********HOLA COMO ESTAN..*************
AYUDA POR FAVOR CON UN MODELO DE DSC ALARMA Q JAMAS VI EN MI VIDA

les cuento tengo un problema con ana alarma dsc 1575-1580 de 6 zonas la cual ya la programe toda pero el unico problema q tengo es que la zona 1 y 2, las tengo con tiempo de entrada y salida el cual ya programe de la siguiente forma , pero "me tengo que quedar quieto" para q se me prenda la luz de listo..??? LES AGRADESCO DE TODO CORAZON FIDOLOCKO..

ACA LES DEJO TODA LA PROGRAMACION COMPLETA DE DSC
ESTA TODO CONFUGURADO PARA Q LLAME POR TELEFONO CUANDO SUENA LA ALARMA, SOLO TIENE Q PONER LOS NUMEROS A LOS Q QUIERAN Q LLAME EN EL PASO 31, 32 Y 33. RECUERDEN Q SOLO DA SEÑAL DE FAX LA IDEA ES PONER EL CELULAR ASI SALE EL NUMERO DE TEL Y CUANDO ATENDES SUENA FAX Y ES POR Q ESTA SONANDO LA ALRMA..

LINK DEL MANUAL DE PROGRAMACION

http://www.avss.net/dsc%20pc1575%20install.pdf

[01] Zone 1-6 Definitions (Section 5.2 “Zone Definitions”)
Default Default
01 I___01____I Zone 1 03 I___03___I Zone 4
06 I___02____I Zone 2 03 I___03___I Zone 5
03 I___03____I Zone 3 03 I___03___I Zone 6
[02] System Times
Default [000-255]
030 I___030___I Entry Delay 1
045 I___030___I Entry Delay 2
120 I___030___I Exit Delay
004 I___004___I Bell Cutoff

[03] Installer’s Code (Section 4 “How to Program”)
Default
1575 I___1____I___5___I___7____I___5____I

[04] Master Code (Section 5.1 “Programming Security Codes”)
Default
1234 I___1____I____2___I___3____I___4____I

[05] Second Master Code (Section 5.1 “Programming Security Codes”)
Default
AAAA I___1____I____1___I___1____I____1___I

Default Default
02 I____0___I____2___I PGM1 08 I____0___I___8____I PGM2

[07] Keypad Lockout Options (Section 5.19 “Keypad Lockout”)
Default
00 I___0____I___5___I Number of Invalid Codes Before Lockout
00 I___0___I____2___I Lockout Duration (in minutes)

[08] First System Option Code
Default Option ON OFF Section
OFF I__APAGADO_______I 1 Normally Closed Loops End-of-Line Resistors 2.8
OFF I___APAGADO______I 2 Double End-of-Line Resistors Single End-of-Line Resistors 2.8
ON I___APAGADO______I 3 [F] Key Enabled [F] Key Disabled 5.13
OFF I___ENCENDIDO_____I 4 [P] Key Audible Bell and Buzzer [P] Key Silent Bell and Buzzer 5.13
ON I___ENCENDIDO_____I 5 TLM Enabled TLM Disabled 5.10
OFF I___ENCENDIDO_____I 6 TLM Audible When Armed TLM Trouble Only When Armed 5.10
[
09] Second System Option Code
Default Option ON OFF Section
OFF I___AP_____I 1 Master Code Not Changeable Master Code Changeable 5.1
OFF I___AP_____I 2 Code Required For Bypassing No Code Required 5.1
OFF I___EN_____I 3 6th Code is Duress Code 6th Code is Normal Code 5.1
OFF I___EN_____I 4 Quick Exit Enabled Quick Exit Disabled 3.4
OFF I___EN_____I 5 Bypass Status Displayed While Armed Bypass Status Not Displayed While Armed 3.4
ON I____EN____I 6 AC Trouble Displayed AC Trouble Not Displayed 3.4

[10] Third System Option Code
Default Option ON OFF Section
OFF I__APA______I 1 Arm / Disarm Bell Squawk Enabled Arm m / Disarm Bell Squawk Disabled 5.14
OFF I___APA_____I 2 Bell Squawk During Auto Arm No Bell Squawk During Auto Arm 5.15
OFF I___APA_____I 3 Bell Squawk On Exit Delay No Bell Squawk On Exit Delay 5.15
OFF I___APA_____I 4 Bell Squawk On Entry Delay No Bell Squawk On Entry Delay 5.15
ON I____ENC____I 5 Audible Exit With Urgency Silent Exit Delay 5.15
ON I____ENC____I 6 Quick Arm Enabled Quick Arm Disabled 3.4

[11] Fourth System Option Code
Default Option ON OFF Section
OFF I___APA_____I 1 For Future Use
ON I____ENC____I 2 Event Buffer Follow Swinger Shutdown Event Buffer Never Shuts Down 5.18
ON I____ENC____I 3 Trouble Light Flashes If AC Fails Trouble Light Does Not Flash If AC Fails 3.4
OFF I___APA_____I 4 Exit Delay Termination Enabled Exit Delay Termination Disabled 5.15
OFF I___APA_____I 5 Keypad Blanking Enabled Keypad Blanking Disabled 5.20
OFF I___ENC_____I 6 Keypad Tampers Enabled Keypad Tampers Disabled 5.22

Zone 1-6 Attributes (Section 5.3 “Zone Attributes”)
Opt. 1 Opt. 2 Opt. 3 Opt. 4 Opt. 5 Opt. 6
On Audible Steady Chime Force Bypass Downlook
Off Silent Pulsed No No No No
[21] Zone 1 I________| I________| I________| I________| I________| I________I
[22] Zone 2 I________| I________| I________| I________| I________I I________I
[23] Zone 3 I________| I________| I________| I________| I________I I________I
[24] Zone 4 I________| I________| I________| I________| I________I I________I
[25] Zone 5 I________| I________| I________| I________| I________I I________I
[26] Zone 6 I________| I________| I________| I________| I________I I________I

Zone Attribute Defaults
Note: For sections [31] to [46], the contents of every section by default is [F].

[31] First Telephone Number (32 Digits) (Section 5.6 “Communicator – Phone Numbers”)

I__X__I__X__I__X__I__X__I__X__I__X__I__X__I__X__I__X__I__X__I__X__I__X__I___X_I____I___

[32] Second Telephone Number (32 Digits) (Section 5.6 “Communicator – Phone Numbers”)
I___X__I__X___I___X__I__X___I___X__I___X__I___X__I___X__I____X_I___X__I_____I_____I_____I

[33] Third Telephone Number (32 Digits) (Section 5.6 “Communicator – Phone Numbers”)
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
[34] First Account Code (4 digits) (Section 5.5 “Communicator – Account Numbers”)
I___1___I___0____I__1____I___0____I

[35] Second Account Code (4 digits) (Section 5.5 “Communicator – Account Numbers”)
I____0___I___0____I___0____I___0____I

[36] Alarm Reporting Codes, Zones 1-6 (Section 5.7 “Communicator – Reporting Codes”)
I____0___I___1____I Zone 1 I___0____I___4____I Zone 4 I___1____I___0____I Police Code Alarm
I____0___I____2___I Zone 2 I___0____I___5____I Zone 5
I____0___I____3___I Zone 3 I___0____I___6____I Zone 6

[37] Alarm Restoral Reporting Codes, Zones 1-6 (Section 5.7 “Communicator – Reporting Codes”)
I_______I_______I Zone 1 I_______I_______I Zone 4 I_______I_______I Opening After Alarm
I_______I_______I Zone 2 I_______I_______I Zone 5
I_______I_______I Zone 3 I_______I_______I Zone 6

[38] Tamper Reporting Codes, Zones 1-6 (Section 5.7 “Communicator – Reporting Codes”)
I_______I_______I Zone 1 I_______I_______I Zone 4 I_______I_______I General System
I_______I_______I Zone 2 I_______I_______I Zone 5 Tamper Alarm
I_______I_______I Zone 3 I_______I_______I Zone 6

[39] Tamper Restoral Reporting Codes, Zones 1-6 (Section 5.7 “Communicator – Reporting Codes”)
I_______I_______I Zone 1 I_______I_______I Zone 4 I_______I_______I General System
I_______I_______I Zone 2 I_______I_______I Zone 5 Tamper Restoral
I_______I_______I Zone 3 I_______I_______I Zone 6

[40] Priority Alarm and Restoral Reporting Codes (Section 5.7 “Communicator – Reporting Codes”)
I_______I_______I Keypad [F]ire Alarm I_______I_______I PGM2 Alarm I_______I_______I Keypad [A]uxiliary Restoral
I_______I_______I Keypad [A]uxiliary Alarm I_______I_______I Duress Code Alarm I_______I_______I Keypad [P]anic Restoral
I_______I_______I Keypad [P]anic Alarm I_______I_______I Keypad [F]ire Restoral I_______I_______I PGM2 Restoral

[41] Closing (Arming) Reporting Codes, Access Codes 1-6 (Section 5.7 “Communicator – Reporting
Codes”)
I_______I_______I Closing by Access Code 1 / 2nd Master / Key switch / Auto Arm
I_______I_______I Closing by Access Code 2 I_______I_______I Closing by Access Code 5
I_______I_______I Closing by Access Code 3 I_______I_______I Closing by Access Code 6
I_______I_______I Closing by Access Code 4 I_______I_______I Partial Closing Code
Communicator Programming

[42] Opening (Disarming) ming) Reporting Codes, Access Codes 1-6 (Section 5.7 “Communicator – Reporting
Codes”)
I_______I_______I Opening by Access Code 1 / 2nd Master / Key switch
I_______I_______I Opening by Access Code 2 I_______I_______I Opening by Access Code 5
I_______I_______I Opening by Access Code 3 I_______I_______I Opening by Access Code 6
I_______I_______I Opening by Access Code 4

[43] Miscellaneous Closing (Arming) Reporting Codes (Section 5.7 “Communicator – Reporting Codes”)
I_______I_______I Battery Trouble Alarm I_______I_______I AUX Fuse Failure Alarm
I_______I_______I AC Failure Trouble Alarm I_______I_______I TLM Trouble Code (via LINKS)
I_______I_______I Bell Circuit Trouble Alarm I_______I_______I General System Supervisory
I_______I_______I Fire Trouble Alarm

[44] Maintenance Restoral Reporting Codes (Section 5.7 “Communicator – Reporting Codes”)
I_______I_______I Battery Trouble Restoral I_______I_______I AUX Fuse Trouble Restoral
I_______I_______I AC Failure Trouble Restoral I_______I_______I TLM Restoral
I_______I_______I Bell Circuit Trouble Restoral I_______I_______I General System Supervisory Restoral
I_______I_______I Fire Trouble Restoral

[45] Miscellaneous Maintenance Reporting Codes (Section 5.7 “Communicator – Reporting Codes”)
I_______I_______I Phone Number 1 Failure to Communicate I_______I_______I General Zone Fault Alarm
I_______I_______I Phone Number 2 Failure to Communicate I_______I_______I General Zone Fault Restoral
I_______I_______I Event Buffer is 75% Full Since Last Upload I_______I_______I Delinquency Reporting Code

[46] Test Transmission Reporting Codes (Section 5.7 “Communicator – Reporting Codes”)
I_______I_______I Periodic Test Transmission
I_______I_______I System Test
I_______I_______I LINKS 1000 Test Transmission Code

[50] Communicator Format Options (Section 5.8 “Communicator – Reporting Formats”)
Default
02 I___0____I___2____I 1st Phone Number
02 I___0____I____2___I 2nd Phone Number
01 20 BPS, 1400 HZ handshake 04 SIA FSK
02 20 BPS, 2300 HZ handshake 05 Pager Format
03 DTMF CONTACT I.D.

[51] Zone Alarms & Restorals Communicator Call Directions (Section 5.4 “Communicator – Dialing”)
Default Option ON OFF
ON I___APA____I 1 1st Telephone Number Disabled
OFF I__APA_____I 2 2nd Telephone Number Disabled
OFF I__APA_____I 3 1st Telephone Number (via LINKS) Disabled
OFF I__APA_____I 4 2nd Telephone Number (via LINKS) Disabled

[52] Zone Tamper Alarms & Tamper Restorals Communicator Call Directions (Section 5.4 “Communicator
– Dialing”)
Default Option ON OFF
ON I___APAGADO_____I 1 1st Telephone Number Disabled
OFF I__APA______I 2 2nd Telephone Number Disabled
OFF I__APA______I 3 1st Telephone Number (via LINKS) Disabled
OFF I__APA______I 4 2nd Telephone Number (via LINKS) Disabled

[53] Openings & Closings Communicator Call Directions (Section 5.4 “Communicator – Dialing”)
Default Option ON OFF
ON I____A____I 1 1st Telephone Number Disabled
OFF I___A_____I 2 2nd Telephone Number Disabled
OFF I___A_____I 3 1st Telephone Number (via LINKS) Disabled
OFF I___A_____I 4 2nd Telephone Number (via LINKS) Disabled

[54] System Maintenance Alarms & Restorals Communicator Call Directions (Section 5.4 “Communicator
– Dialing”)
Default Option ON OFF
ON I__A______I 1 1st Telephone Number Disabled
OFF I__A______I 2 2nd Telephone Number Disabled
OFF I__A______I 3 1st Telephone Number (via LINKS) Disabled
OFF I__A______I 4 2nd Telephone Number (via LINKS) Disabled

[55] System Test Transmissions Communicator Call Directions (Section 5.4 “Communicator – Dialing”)
Default Option ON OFF
ON I___A_____I 1 1st Telephone Number (Periodic Test TX and System Test Only) Disabled
OFF I___A_____I 2 2nd Telephone Number (Periodic Test TX and System Test Only) Disabled
OFF I___A_____I 3 1st Telephone Number (via LINKS) (LINKS 1000 Test TX Code Only) Disabled
OFF I___A_____I 4 2nd Telephone Number (via LINKS) (LINKS 1000 Test TX Code Only) Disabled

[60] First Communicator Option Code
Default Option ON OFF Section
ON I___ENC____I 1 Communications Enabled Communications Disabled 5.4
ON I___ENC____I 2 DTMF Dialing Pulse Dialing 5.4
ON I___APA____I 3 Switch to Pulse Dialing on 5th Attempt DTMF Dial For All 8 Attempts 5.4
OFF I__ENCE_____I 4 3rd Phone Number Enabled 3rd Phone Number Disabled 5.6
OFF I__ENCE_____I 5 Alternate Dial (1st and 3rd) Call 1st Number, Backup to 3rd (If programmed) 5.6
OFF I__APA_____I 6 Restorals on Bell Time-out Restorals Follow Zones 5.7.2

[61] Second Communicator Option Code
Default Option ON OFF Section
OFF I___ENC____I 1 Closing Confirmation Enabled Closing Confirmation Disabled 5.7.3
OFF I___ENC____I 2 Opening After Alarm Keypad Open After Alarm Bell Ringback Disabled 5.7.4
Ringback Enabled
OFF I___APA____I 3 Opening After Alarm Bell Opening After Alarm Bell Ringback Disabled 5.7.4
Ringback Enabled
OFF I___A____I 4 Busy Tone Detection Enabled Busy Tone Detection Disabled 5.4
OFF I___A____I 5 Call LINKS As Well As Land Line LINKS is Backup of Land Line(s)
OFF I___A____I 6 SIA Sends Programmed Rep. Codes SIA Sends Automatic Rep. Codes 5.8.3

[62] Communication Variables
Default Section
003 I____0___I___2____I___0____I Swinger Shutdown (Alarms and Rest) (001-014 Transmissions, 000=disabled) 5.16
000 I____0___I___0____I___1____I Transmission Delay (001-255 seconds) 5.17
030 I____0___I___0____I___1____I AC Failure Communication Delay (001-255 minutes) 5.7.7
003 I____0___I___0____I___1____I TLM Trouble Delay (No. of valid checks required - 000-255 x 10s) 5.10
030 I____0___I___0____I___1____I Test Transmission Cycle (001-255 days) 5.12
030 I____0___I___0____I___1____I Delinquency Transmission Delay (000-255 days) 5.7.9

[63] Test Transmission Time of Day (Section 5.12 “Test Transmission”)
Default
9999 I_______I_______I_______I_______I (Valid entries are 0000-2359, 9999 to disable)


[67] LINKS 1000 Preamble (First Telephone Number) (Section 5.23 “LINKS 1000 Cellular Communicator”)
Default
FFFF I_______I_______I_______I_______I (Program all unused digits with Hex F)

[68] LINKS 1000 Preamble (Second Telephone Number) (Section 5.23 “LINKS 1000 Cellular Communicator”)
Default
FFFF I_______I_______I_______I_______I (Program all unused digits with Hex F)

[69] LINKS 1000 Preamble (Third Telephone Number) (Section 5.23 “LINKS 1000 Cellular Communicator”)
Default
FFFF I_______I_______I_______I_______I (Program all unused digits with Hex F)

[70] Number of Rings to Answer On (Section 5.9 “Downloading”)
Default
1 2 I_______I_______I (Valid entries are 00-99)

[71] First Downloading Option Code (Section 5.9 “Downloading”)
Default Option ON OFF
OFF I___EN____I 1 Downloading Answer Enabled Downloading Answer Disabled
ON I____EN___I 2 User Can Enable DLS Window for One Hour User Cannot Enable DLS Window
OFF I___EN____I 3 Call-Back Enabled Call-Back Disabled
OFF I___EN____I 4 User Initiated Call-up Enabled User Initiated Call-up Disabled
OFF I___EN____I 5 Periodic Download at Test TX Time No Periodic Download
OFF I___EN____I 6 Answering Machine Override Enabled Answering Machine Override Disabled

[72] Downloading Computer’s Telephone Number (32 Digits) (Section 5.9 “Downloading”)
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
[73] Downloading Access Code (Section 5.9 “Downloading”)
Default
1575 I_______I_______I_______I_______I Enter 4 Hexadecimal Digits

[74] Panel Identification Code (Section 5.9 “Downloading”)
Default
1575 I_______I_______I_______I_______I Enter 4 Hexadecimal Digits

[75] Answering Machine Double-call Timer (Section 5.9 “Downloading”)
Default
060 I_______I_______I_______I (Valid entries are 001-255 seconds)

[77] [Installer Code] [77] Initiate Local Downloading (PC-LINK) (Section 5.9 “Downloading”)

[79] LINKS 1000 Preamble (Downloading Telephone Number) (Section 5.9 “Downloading”)
Default
FFFF I_______I_______I_______I_______I (Program all unused digits with Hex F)
Downloading Programming

[87]PC5400 Programming (Printer Module) (Section 5.24 “On-Site Printer”)
[01] Printer Configuration
Default Option ON OFF
OFF I________I 1 Printer Enabled Printer Disabled
ON I________I 2 Handshake from Printer No Handshake
OFF I________I 3 80 Column Printer 40 Column Printer
OFF I________I 4 300 Baud Enabled Disabled
OFF I________I 5 1200 Baud Enabled Disabled
ON I________I 6 2400 Baud Enabled Disabled
[05] Printer Language Selection
Default
01 I________I________I (01=English 02=French 03=Spanish)

[88] DLM-1/DLM-4 Support Timers (Section 5.25 “Downlook Video Transmission Module”)
Default
01 I________I________I Number of Pictures (Valid Entries are 01-0
00 I________I________I Delay Before Capture at 100ms increments (Valid Entries are 00-99)

[90] [Installer’s Code] [90] Installer Lockout Enable (Section 5.27 “Installer’s Lockout”)
Enter [90] [Installer’s Code] [90]

[91] [Installer’s Code] [91] Installer Lockout Disable (Section 5.27 “Installer’s Lockout”)
Enter [91] [Installer’s Code] [91]

[92] [Installer’s Code] [92] Module Supervision Reset (Section 2.6 “Supervision”)
Enter [91] [Installer’s Code] [91]

[95] [Installer’s Code] [95] Restore ESCORT to Factory Default Programming (Section 5.26 “Resetting
Factory Defaults”)
Enter [95] [Installer’s Code] [95]

[97] [Installer’s Code] [97] Restore PC5400 to Factory Default Programming (Section 5.26 “Resetting
Factory Defaults”)
Enter [96] [Installer’s Code] [96]

[99] [Installer’s Code] [99] Restore PC1575 to Factory Default Programming (Section 5.26 “Resetting
Factory Defaults”)
Enter [99] [Installer’s Code] [99]